Home>Products>Water Purification Solutions>PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
DuPont Ultrafiltration PD-77-1 MODELS
Need a CAD or 3D Model?
PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
category
Water Purification Solutions
DuPont Ultrafiltration PD-77-1 SPECIFICATIONS
PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid WATER TREATMENT SOLUTIONS MANUFACTURER with easy-to-use parts graphics, giving you the ability to check parts availability, Water Purification Solutions pricing, examine Low Fouling Type remanufactured options.
- DuPont Ultrafiltration
PD-77-1
- Low Fouling
- 10200
- 38.4
- TML20-400
- 101.6
- 40
- 4136.87
- 600
-
WATER TREATMENT SOLUTIONS MANUFACTURER2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
Types of PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
- 45.0
- 113
- 37.1
- 400
- 99.7 %
- 99.0 %
DuPont Ultrafiltration PD-77-1 Specifications for PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid RELATED CATEGORIES | |||||||||
---|---|---|---|---|---|---|---|---|---|
No. | Brand | Type | Flow gpm | pH range | Length mm | Weight kg | Weight lb | Application | Flow m3/day |
IPD-77-10 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Drinking Water | 220 | 2-11 | 1967 | 791 | 1744 | Ultra pure water, Beverage, Boiler water | 1200 |
IPD-77-12 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Drinking Water | 264 | 2-11 | 2330 | 939 | 2070 | Ultra pure water, Beverage, Boiler water | 1440 |
IPD-77-14 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Drinking Water | 309 | 2-11 | 2693 | 1091 | 2406 | Ultra pure water, Beverage, Boiler water | 1685 |
IPD-77-16 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Drinking Water | 353 | 2-11 | 3056 | 1249 | 2754 | Ultra pure water, Beverage, Boiler water | 1925 |
IPD-77-18 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Drinking Water | 397 | 2-11 | 3419 | 1401 | 3089 | Ultra pure water, Beverage, Boiler water | 2165 |
SFP 2860 XP DuPont Ultrafiltration IntegraFlux Ultrafiltration Module | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
NF-254 DuPont Ultrafiltration Nanofiltration Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
XUS120304 Filmtec Membranes High Temperature RO Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
TMG20-43 Toray Membranes Brackish Water Reverse Osmosis Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
RE-2521-BLF Toray Membranes Membrane | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
TMR140-400DW Toray Membranes Brackish Water Reverse Osmosis Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
TW30LE-404 Filmtec Membranes Tapwater RO Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
TW30-1812-36 Filmtec Membranes Small Commercial Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
SW30-2514 Filmtec Membranes Seawater Reverse Osmosis Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
ECO-500i DuPont Ultrafiltration High Rejection Reverse Osmosis Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
LP-254 DuPont Ultrafiltration Low Pressure RO Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
TM820E-4 Toray Membranes Sea Water Reverse Osmosis Element | Type:Low Fouling; Brand:Toray Membranes; Flow gpd:10200; Flow m3/day:38.4; Part Number:TML20-400; Length in cm:101.6; Length in inch:40; Max Pressure kPa:4136.87; Max Pressure psi:600; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Average NaCl rejection percentage:99.7 %; Minimum NaCl rejection percentage:99.0 %; |
PD-77-1 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Video
Contact Us

- WATER TREATMENT SOLUTIONS MANUFACTURER
DuPont Ultrafiltration PD-77-1 Technical Articles
How can I naturally purify my well water? |
How many types of water treatments are there? |
What are the seven stages of water treatment? |