Home>Products>Water Technologies & Solutions>P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
DuPont Ultrafiltration P-77XP-14 MODELS
Need a CAD or 3D Model?
P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid
category
Water Technologies & Solutions
DuPont Ultrafiltration P-77XP-14 SPECIFICATIONS
What are the types of P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Seawater Type ? Water Technologies & Solutions Manufacturing Service . Get Your WATER TREATMENT SOLUTIONS MANUFACTURER Free, Instant price, design review.
- DuPont Ultrafiltration
P-77XP-14
- Seawater
- 9000
- 33.9
- SWC5-LD
- 101.6
- 40
- 82.74
- 1200
-
WATER TREATMENT SOLUTIONS MANUFACTURER2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Specification details
- 45.0
- 113
- 37.1
- 400
- 16.4
- 36.2
- 99.8 %
- 99.7 %
DuPont Ultrafiltration P-77XP-14 P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Exchange Guide
P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid cross reference chart | |||||||||
---|---|---|---|---|---|---|---|---|---|
No. | Brand | Type | Flow gpm | pH range | Length mm | Weight kg | Weight lb | Application | Flow m3/day |
IP-77XP-14 IntegraPac Ultrafiltration Skid | DuPont Ultrafiltration | Industrial | 309 | 2-11 | 2693 | 1091 | 2406 | Ultra pure water, Beverage, Boiler water | 1685 |
RE-8040-BE34 Toray Membranes Membrane | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
RE-2540-FE Toray Membranes Membrane | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
RE-8040-FD Toray Membranes Membrane | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
BW30-400/34 DuPont Ultrafiltration Reverse Osmosis Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
NE-2540-7 Toray Membranes Membrane | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
NF 270 400/34i Filmtec Membranes RO and Desalination Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
XUS120308 DuPont Ultrafiltration High Temperature RO Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
SUL-G10P Toray Membranes Energy Saving RO Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
SW30-2521 Filmtec Membranes Seawater Reverse Osmosis Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
TM840R-176 Toray Membranes Sea Water Reverse Osmosis Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
TM820C-37 Toray Membranes Sea Water Reverse Osmosis Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
SW30-4021 DuPont Ultrafiltration Seawater Reverse Osmosis Element | Type:Seawater; Brand:Hydranautics Membranes; Flow gpd:9000; Flow m3/day:33.9; Part Number:SWC5-LD; Length in cm:101.6; Length in inch:40; Max Pressure kPa:82.74; Max Pressure psi:1200; Max Temperature °C:45.0; Max Temperature °F:113; Membrane Active Area m2:37.1; Membrane Active Area ft2:400; Carton shipping weight in kg:16.4; Carton shipping weight in lbs:36.2; Average NaCl rejection percentage:99.8 %; Minimum NaCl rejection percentage:99.7 %; |
P-77XP-14 DuPont Ultrafiltration IntegraPac Ultrafiltration Skid Video
DuPont Ultrafiltration IP-77XP IntegraPac Ultrafiltration Module
Ultrafiltration (UF) is a pressure-driven purification process that separates particulate matter from soluble compounds using an ultrafine membrane media.
BASF to sell its ultrafiltration membrane business to DuPont
Sep 24, 2019 — BASF and DuPont Safety & Construction (DuPont) today announced that the companies have signed an agreement where BASF will sell its ...
NSF Product and Service Listings
DOW IntegraPac Ultrafiltration Skid IPD-77XP-14[2], [6], CLD 23, MLTPL ... DuPont Memcor (Australia) Pty Ltd ... dizzer® L 0.9 MB 28 P, N/A, CLD 23, MLTPL.
Water; Recovery, Reclamation and Recycling within the Irish Dairy ...
Osmosis technologies were investigated with UF showing the least promise and RO the ... membranes. 300. IP-51XP. IP-77XP. DuPont. Filmtec.
Developing Design Standards to enable the use of innovative ...
by ME Patterson · 2020 — Figure 7: Internal view of Toray Hollow Fiber UF Module (Toray, n.d.) . ... Figure 14: Illustration of UF Membrane Fouling by Iron and Manganese at varied ...
Guillem Gilabert-Oriol, DuPont Water Solutions - Aedyr
Source: Stephen P et al. Results from 99 seawater. RO membrane autopsies (2011). 2002-. 2010. Main Reason for RO Membranes Failure.
MEMBRANE ULTRAFILTRAZIONE ULTRAFILTRATION ...
The DuPont Ultrafiltration Modules are made of high strength, hollow fiber membranes with features and benefits including: • 0.03 µm nominal pore diameter for ...40 pages
IntegraPac™ IPD-77XP Module - DuPont
IntegraPac IPD-77XP Modules are made from high-strength, PVDF hollow fiber membranes engineered to reduce design and fabrication requirements. The fibers have a ...
Contact Us

- WATER TREATMENT SOLUTIONS MANUFACTURER
DuPont Ultrafiltration P-77XP-14 Technical Articles
How can I naturally purify my well water? |
How many types of water treatments are there? |
What are the seven stages of water treatment? |